Share this page

Clinical Chemistry Analyzer “CA Series”

Clinical Chemistry Analyzer “CA Series”

FURUNO ELECTRIC CO., LTD.

Clinical Chemistry Analyzer "CA Series"

Three models with different throughputs can cover from small to large scale facilities. Two of the smaller models are a benchtop type and can be installed anywhere.

CA-800

CA-270

CA-400

Major Features and Advantages

  • Our products realize smaller minimum reaction volume compared with equivalent products, leading to "reduction of patient burden with smaller amount of blood collection," "reduction of water consumption and infectious wastewater with lower usage of water for washing", and "more reasonable test cost with smaller reagent volume”.
  • Some models are equipped with automatic hemolysis function for red blood cells, enabling simultaneous measurement of blood glucose and HbA1c from a single blood collection tube.

Reagent for "CA Series"

Technology Data

Technology data

Possible applications

  • Distributing our analyzers with smaller reagent consumption will increase the opportunities for the poor by more reasonable test cost.
  • Our product line-up is suited for different sizes of facilities: CA-270 is for clinics or hospitals with about 100 beds, CA-400 is for hospitals with 100 to 300 beds, and CA-800 is for hospitals with more than 300 beds.
  • While wide range of clinical chemistry and immunoturbidimetric tests are available in our products, liver functions (ALP, ALT, AST, γGTP, etc.), kidney functions (Cre, Urea, μTP, etc.), lipids (TG, Cho, HDL-C, LDL-C, etc.), and diabetes (Glu, HbA1c, etc.) are the popular tests among developing countries.
  • Lower volume of infectious wastewater (including water for washing) will ease the burden on sewage treatment facilities.
  • Our robust and trouble-free design enables testing with minimal downtime, even in underserved developing countries.

The product life of 7 years is achieved by the durability design considering the life of each component and the verification process through continuous operation tests on prototypes. Any parts which fail to achieve the life of 7 years are defined as periodic replacement parts or service parts, and are designed to be easily replaced.

Working hours of the analyzer is controlled in the software and it allows the users to effectively manage the replacement of such parts.

Competitive advantage

【Realization of micro sampling】

  1. Minimum reaction volume
    Extremely low minimum reaction volume was achieved by downsizing the diameter of optical axis, designing non-spherical lens to minimize spherical aberration and its optimal layout, and optimization of glass materials. The lower reaction volume leads to less use of water, infectious wastewater and reagents.
  2. Sampling volume
    Use of a nozzle shape with minimal pressure loss and precise driving control of the plunger minimized the sampling volume per unit.

Performance

  1. Minimum reaction volume
    CA-800: 50 μL (at least 50% lower than equivalent models of other companies)
    CA-270: 100 μL (at least 20% lower than equivalent models of other companies)
  1. Sampling volume
    CA-800: 0.5 μL (at least 50% lower than equivalent models of other companies)
    CA-270: 1.5 μL (at least 25% lower than equivalent models of other companies)

Technical maturity / Past record of introduction

  • FURUNO as manufacturer 
    CA-270
    South Korea, Russia, Brazil, Thailand, Iran, Italy, Germany, China, Vietnam, Indonesia, Philippines, etc.
    CA-400
    Costa Rica, Saudi Arabia, Italy, South Korea, Russia, Malaysia, Thailand, Brazil, China, India, Vietnam, etc.
    CA-800
    China, Russia, Vietnam, Thailand, etc.

  • OEM products
    *Including all clinical chemistry products
    EU, African countries, India, China, Russia, UAE, Brazil, Viet Nam, Indonesia, Malaysia, Puerto Rico, US, Mexico, Thailand etc.

Information on patent related to this technology

  • Unexamined patent application 2006-126016: High precision  micro volume measurement technology
  • Unexamined patent application 2010-101726
  • Unexamined patent application 2011-095058、226868
  • Unexamined patent application 2017-090331,090355
  • Unexamined patent application 2019-214027

Company Data

Company data

Name FURUNO ELECTRIC CO., LTD.
Address 9-52 Ashihara-cho, Nishinomiya City, Hyogo. 662-8580, Japan
Capital 7,534 million JPY
Contact person Mr. Kenji KITAGAWA
TEL: +81-798-33-7517
Email:support.medical01@furuno.co.jp
Number of employees 2,978 (as of November 2021)
Date of company foundation May 23, 1951
Type of business Manufacturing and sale of maritime, industrial and medical electronic products.

International operation

Number of employees for international operation 
974
Overseas offices

City, Country Name of Company (if applicable)
Indonesia and 21 other countries PT FURUNO ELECTRIC INDONESIA  Other 31 companies

Modality of business transaction

Partnership

We will play a role in improving local medical standards by providing simple and accurate test results at reasonable cost using our automated analyzers to replace less imprecise test methods such as hand methods and semi-automatic tests. Although we basically export finished products, we may consider sending parts and asking our partners to conduct final assembly, depending on the regulations and sales volume of the target country. (We have experience in Brazil and China.) 

Export of product
We provide technical service training to local distributors so that the continuous operation of the analyzers is established locally.

Contact Person(s)

Mr. Kenji KITAGAWAE-mail: support.medical01@furuno.co.jp

*Please mention that you saw UNIDO's website when making the first contact with the company.

Registered Category

  • Human Health Technologies : Monitoring and diagnostic equipment